Tutto sull’automazione industriale, la manutenzione delle flotte e la tecnologia di riparazione. Notizie sul settore, prodotti consigliati, produttori leader e sviluppi nel settore RGB, tutto in un unico posto. Siamo lieti di condividere le competenze ingegneristiche, le opinioni dei tecnici e degli specialisti delle apparecchiature RGB. Vi invitiamo a sfogliare e scaricare il materiale.

Trova il codice di errore
| Codice di errore | Prodotto | Categoria di apparecchiatura | Descrizione |
|---|---|---|---|
| 4163 | Baumüller | Module G to M P0245 to P0250 |
Cmd interface: Wrong status when handling the package |
| 4164 | Baumüller | Module G to M P0245 to P0250 |
Cmd interface: Timeout at command processing |
| 4165 | Baumüller | Module G to M P0245 to P0250 |
Cmd interface: Wrong package length |
| 4166 | Baumüller | Module G to M P0245 to P0250 |
Cmd interface: Descriptor not available |
| 4167 | Baumüller | Module G to M P0245 to P0250 |
Cmd interface: Wrong package type |
| 4168 | Baumüller | Module G to M P0245 to P0250 |
Cmd interface: Checksum error |
| 4169 | Baumüller | Module G to M P0245 to P0250 |
Module identification: PCI-Error when reading |
| 417 | Fanuc | Servo amplifier 400 alarms |
SERVO ALARM: n–TH AXIS – PARAMETER INCORRECT – This alarm occurs when the n–th axis (axis 1–8) is in one of the conditions listed below. (Digital servo system alarm) 1) The value set in Parameter No. 2020 (motor form) is out of the specified limit. 2) A proper value (111 or –111) is not set in parameter No.2022 (motor revolution direction). 3) Illegal data (a value below 0, etc.) was set in parameter No. 2023 (number of speed feedback pulses per motor revolution). 4) Illegal data (a value below 0, etc.) was set in parameter No. 2024 (number of position feedback pulses per motor revolution). 5) Parameters No. 2084 and No. 2085 (flexible field gear rate) have not been set. 6) A value outside the limit of {1 to the number of control axes} or a non–continuous value (Parameter 1023 (servo axis number) contains a value out of the range from 1 to the number of axes, or an isolated value (for example, 4 not preceded by 3) was set in parameter No. 1023 (servo axisnumber). 7) The amplifier in use does not support the HC alarm avoidance function. If you want to use this amplifier, reset the function bit 2209#4 to 0. If you want to use the HC alarm avoidance function, use an amplifier that supports it. |
| 4170 | Baumüller | Module G to M P0245 to P0250 |
Module identification: PCI-Error when writing |
| 4170 | Siemens | Simodrive 611 |
Invalid M function number for channel synchronisation assigned |
| 4171 | Baumüller | Module G to M P0245 to P0250 |
Module identification: general Reading error |
| 4172 | Baumüller | Module G to M P0245 to P0250 |
Module identification: general Error at writing |
| 4173 | Baumüller | Module G to M P0245 to P0250 |
Internal error |
| 4174 | Baumüller | Module G to M P0245 to P0250 |
Configuration cyclic services: Parameters are not cyclic writeable |
| 4175 | Baumüller | Module G to M P0245 to P0250 |
Configuration cyclic services: Invalid parameter number |
| 4176 | Baumüller | Module G to M P0245 to P0250 |
Wrong option module error code |
| 4177108191 | Baumüller | Module G to M P0245 to P0250 |
reserved |
| 4180 | Siemens | Simodrive 611 |
Invalid M function number assigned to enable ASUP |
| 4181 | Siemens | Simodrive 611 |
Channel %1 invalid assignment of an M auxiliary function number |
| 4182 | Siemens | Simodrive 611 |
Channel %1 invalid M auxiliary function number in %2%3, MD reset |