Tutto sull’automazione industriale, la manutenzione delle flotte e la tecnologia di riparazione. Notizie sul settore, prodotti consigliati, produttori leader e sviluppi nel settore RGB, tutto in un unico posto. Siamo lieti di condividere le competenze ingegneristiche, le opinioni dei tecnici e degli specialisti delle apparecchiature RGB. Vi invitiamo a sfogliare e scaricare il materiale.

RGB Elektronika

Trova il codice di errore

Codice di errore Prodotto Categoria di apparecchiatura Descrizione
4163 Baumüller Module G to M P0245 to P0250

Cmd interface: Wrong status when handling the package

4164 Baumüller Module G to M P0245 to P0250

Cmd interface: Timeout at command processing

4165 Baumüller Module G to M P0245 to P0250

Cmd interface: Wrong package length

4166 Baumüller Module G to M P0245 to P0250

Cmd interface: Descriptor not available

4167 Baumüller Module G to M P0245 to P0250

Cmd interface: Wrong package type

4168 Baumüller Module G to M P0245 to P0250

Cmd interface: Checksum error

4169 Baumüller Module G to M P0245 to P0250

Module identification: PCI-Error when reading

417 Fanuc Servo amplifier 400 alarms

SERVO ALARM: n–TH AXIS – PARAMETER INCORRECT – This alarm occurs when the n–th axis (axis 1–8) is in one of the conditions listed below. (Digital servo system alarm) 1) The value set in Parameter No. 2020 (motor form) is out of the specified limit. 2) A proper value (111 or –111) is not set in parameter No.2022 (motor revolution direction). 3) Illegal data (a value below 0, etc.) was set in parameter No. 2023 (number of speed feedback pulses per motor revolution). 4) Illegal data (a value below 0, etc.) was set in parameter No. 2024 (number of position feedback pulses per motor revolution). 5) Parameters No. 2084 and No. 2085 (flexible field gear rate) have not been set. 6) A value outside the limit of {1 to the number of control axes} or a non–continuous value (Parameter 1023 (servo axis number) contains a value out of the range from 1 to the number of axes, or an isolated value (for example, 4 not preceded by 3) was set in parameter No. 1023 (servo axisnumber). 7) The amplifier in use does not support the HC alarm avoidance function. If you want to use this amplifier, reset the function bit 2209#4 to 0. If you want to use the HC alarm avoidance function, use an amplifier that supports it.

4170 Baumüller Module G to M P0245 to P0250

Module identification: PCI-Error when writing

4170 Siemens Simodrive 611

Invalid M function number for channel synchronisation assigned

4171 Baumüller Module G to M P0245 to P0250

Module identification: general Reading error

4172 Baumüller Module G to M P0245 to P0250

Module identification: general Error at writing

4173 Baumüller Module G to M P0245 to P0250

Internal error

4174 Baumüller Module G to M P0245 to P0250

Configuration cyclic services: Parameters are not cyclic writeable

4175 Baumüller Module G to M P0245 to P0250

Configuration cyclic services: Invalid parameter number

4176 Baumüller Module G to M P0245 to P0250

Wrong option module error code

4177108191 Baumüller Module G to M P0245 to P0250

reserved

4180 Siemens Simodrive 611

Invalid M function number assigned to enable ASUP

4181 Siemens Simodrive 611

Channel %1 invalid assignment of an M auxiliary function number

4182 Siemens Simodrive 611

Channel %1 invalid M auxiliary function number in %2%3, MD reset