Tutto sull’automazione industriale, la manutenzione delle flotte e la tecnologia di riparazione. Notizie sul settore, prodotti consigliati, produttori leader e sviluppi nel settore RGB, tutto in un unico posto. Siamo lieti di condividere le competenze ingegneristiche, le opinioni dei tecnici e degli specialisti delle apparecchiature RGB. Vi invitiamo a sfogliare e scaricare il materiale.

Trova il codice di errore
| Codice di errore | Prodotto | Categoria di apparecchiatura | Descrizione |
|---|---|---|---|
| 01.1 | Fanuc | Servo amplifier alarms |
DC voltage of the main circuit power supply is abnormally high. Internal cooling circuit faulty Overcurrent flowed into the input of the main circuit. Input supply voltage imbalance, IGBT defective. (PSM-15 to PSM-55) The battery voltage of the absolute pulse coder is low. (warning) The main circuit power module (IPM) has detected an overload, overcurrent, or control supply voltage decrease, overcurrent, or control supply voltage decrease. Internal cooling circuit failure, Overload, Input supply voltage imbalance, IPM failure, or control supply voltage decrease of the power module. |
| 02.2 | Fanuc | Servo amplifier alarms |
Internal cooling circuit faulty. Inverter: control power supply undervoltage The battery voltage of the absolute pulse coder is low. |
| 03.3 | Fanuc | Servo amplifier alarms |
DC voltage of the main circuit power supply is abnormally low or the circuit breaker is tripped. The motor has overheated (OHAL). The temperature of the heat sink has risen. |
| 04.4 | Fanuc | Servo amplifier alarms |
DC voltage (DC link) has dropped Regenerative discharge energy is too high. –The regenerative discharge circuit is abnormal. Servo motor has overheated (estimated value). |
| 05.5 | Fanuc | Servo amplifier alarms |
Average regenerative discharge energy is too high (too frequent acceleration/deceleration) –The transformer overheats. Inverter: DC link undervoltage The input power supply is abnormal (open phase) or the main circuit capacitor was not recharged within the specified time. |
| 06.6 | Fanuc | Servo amplifier alarms |
Inverter: Overheat |
| 07.7 | Fanuc | Servo amplifier alarms |
MCC is faulty. Relay contacts for the dynamic brake is faulty. The DC link voltage is abnormally high. |
| 08.8 | Fanuc | Servo amplifier alarms |
Abnormal current alarm (L axis) The offset of the current detection circuit of the main circuit DC link is excessive. The regenerative discharge unit is heated. |
| 09.9 | Fanuc | Servo amplifier alarms |
Abnormal current alarm (M axis) Reference position setting cannot be executed correctly. |
| 1 | Baumüller | Encoder 1 - serial interface P0234, encoder 2 - serial interface P0 235 |
Analog signals outside specification |
| 1 | Baumüller | Finding notch position P0237 |
Overcurrent step 2 Error occurs at 180 % of maximum current P1241 |
| 1 | Baumüller | Mains monitor P0236 |
Mains monitor has detected error Phase failure |
| 1 | Baumüller | Module A to E P0240 to P0244 |
Module not recognized |
| 1 | Baumüller | Power supply P0261 |
Undervoltage 24V |
| 1 | Baumüller | Procesor P0201 |
Watchdog-Error |
| 10 | Baumüller | Encoder 1 - serial interface P0234, encoder 2 - serial interface P0 235 |
Checksum error |
| 10 | Baumüller | Module A to E P0240 to P0244 |
AI0-04: Current < 4 mA |
| 10 | Baumüller | Power unit - serial interface P0233 |
Checksum error |
| 100 | Baumüller | Encoder 1 - serial interface P0234, encoder 2 - serial interface P0 235 |
Error undervoltage |
| 100 | Baumüller | Motor P0207 |
Power unit maximal current > motor maximal current |