Tutto sull’automazione industriale, la manutenzione delle flotte e la tecnologia di riparazione. Notizie sul settore, prodotti consigliati, produttori leader e sviluppi nel settore RGB, tutto in un unico posto. Siamo lieti di condividere le competenze ingegneristiche, le opinioni dei tecnici e degli specialisti delle apparecchiature RGB. Vi invitiamo a sfogliare e scaricare il materiale.

RGB Elektronika

Trova il codice di errore

Codice di errore Prodotto Categoria di apparecchiatura Descrizione
4148 Baumüller Module G to M P0245 to P0250

BACI timeout at cyclic data

4149 Baumüller Module G to M P0245 to P0250

BACI timeout at Service data

415 Fanuc Servo amplifier 400 alarms

SERVO ALARM: n–TH AXIS – EXCESS SHIFT – A speed higher than 511875 units/s was attempted to be set in the n–th axis (axis 1–8). This error occurs as the result of improperly set CMR.

4150 Baumüller Module G to M P0245 to P0250

Check results in faulty checksum

4150 Siemens Simodrive 611

Channel %1 invalid M function sub program call configured

4151 Baumüller Module G to M P0245 to P0250

ramp-up Timeout when waiting for the slave type or when waiting for the resetting of config-pending-flag

4152 Baumüller Module G to M P0245 to P0250

Invalid data transfer structure type

4152 Siemens Simodrive 611

Illegal configuration of the “Block display with absolute values” function

4153 Baumüller Module G to M P0245 to P0250

Internal error: Wrong BACI status

4154 Baumüller Module G to M P0245 to P0250

Access conflicts with slave at cyclic Communication

4155 Baumüller Module G to M P0245 to P0250

Error cyclic Communication: Parameter value wrong

4156 Baumüller Module G to M P0245 to P0250

Error cyclic Communication: Alive- counter conflict

4157 Baumüller Module G to M P0245 to P0250

Channel number wrong (0 or > 6) Cmd interface:

4158 Baumüller Module G to M P0245 to P0250

Cmd interface: The channel which was indicated does not exist

4159 Baumüller Module G to M P0245 to P0250

Cmd interface: Internal error – wrong pointer

416 Fanuc Servo amplifier 400 alarms

SERVO ALARM: n–TH AXIS – DISCONNECTION – Position detection system fault in the n–th axis (axis 1–8) pulse coder (disconnection alarm). Refer to diagnosis display No. 201 for details.

4160 Baumüller Module G to M P0245 to P0250

Cmd interface: Internal error – wrong status

4160 Siemens Simodrive 611

Channel %1 invalid M function number configured for spindle switchover

4161 Baumüller Module G to M P0245 to P0250

Cmd interface: Wrong package number

4162 Baumüller Module G to M P0245 to P0250

Cmd interface: Wrong command number