Tutto sull’automazione industriale, la manutenzione delle flotte e la tecnologia di riparazione. Notizie sul settore, prodotti consigliati, produttori leader e sviluppi nel settore RGB, tutto in un unico posto. Siamo lieti di condividere le competenze ingegneristiche, le opinioni dei tecnici e degli specialisti delle apparecchiature RGB. Vi invitiamo a sfogliare e scaricare il materiale.

Trova il codice di errore
| Codice di errore | Prodotto | Categoria di apparecchiatura | Descrizione |
|---|---|---|---|
| 4148 | Baumüller | Module G to M P0245 to P0250 |
BACI timeout at cyclic data |
| 4149 | Baumüller | Module G to M P0245 to P0250 |
BACI timeout at Service data |
| 415 | Fanuc | Servo amplifier 400 alarms |
SERVO ALARM: n–TH AXIS – EXCESS SHIFT – A speed higher than 511875 units/s was attempted to be set in the n–th axis (axis 1–8). This error occurs as the result of improperly set CMR. |
| 4150 | Baumüller | Module G to M P0245 to P0250 |
Check results in faulty checksum |
| 4150 | Siemens | Simodrive 611 |
Channel %1 invalid M function sub program call configured |
| 4151 | Baumüller | Module G to M P0245 to P0250 |
ramp-up Timeout when waiting for the slave type or when waiting for the resetting of config-pending-flag |
| 4152 | Baumüller | Module G to M P0245 to P0250 |
Invalid data transfer structure type |
| 4152 | Siemens | Simodrive 611 |
Illegal configuration of the “Block display with absolute values” function |
| 4153 | Baumüller | Module G to M P0245 to P0250 |
Internal error: Wrong BACI status |
| 4154 | Baumüller | Module G to M P0245 to P0250 |
Access conflicts with slave at cyclic Communication |
| 4155 | Baumüller | Module G to M P0245 to P0250 |
Error cyclic Communication: Parameter value wrong |
| 4156 | Baumüller | Module G to M P0245 to P0250 |
Error cyclic Communication: Alive- counter conflict |
| 4157 | Baumüller | Module G to M P0245 to P0250 |
Channel number wrong (0 or > 6) Cmd interface: |
| 4158 | Baumüller | Module G to M P0245 to P0250 |
Cmd interface: The channel which was indicated does not exist |
| 4159 | Baumüller | Module G to M P0245 to P0250 |
Cmd interface: Internal error – wrong pointer |
| 416 | Fanuc | Servo amplifier 400 alarms |
SERVO ALARM: n–TH AXIS – DISCONNECTION – Position detection system fault in the n–th axis (axis 1–8) pulse coder (disconnection alarm). Refer to diagnosis display No. 201 for details. |
| 4160 | Baumüller | Module G to M P0245 to P0250 |
Cmd interface: Internal error – wrong status |
| 4160 | Siemens | Simodrive 611 |
Channel %1 invalid M function number configured for spindle switchover |
| 4161 | Baumüller | Module G to M P0245 to P0250 |
Cmd interface: Wrong package number |
| 4162 | Baumüller | Module G to M P0245 to P0250 |
Cmd interface: Wrong command number |