Tutto sull’automazione industriale, la manutenzione delle flotte e la tecnologia di riparazione. Notizie sul settore, prodotti consigliati, produttori leader e sviluppi nel settore RGB, tutto in un unico posto. Siamo lieti di condividere le competenze ingegneristiche, le opinioni dei tecnici e degli specialisti delle apparecchiature RGB. Vi invitiamo a sfogliare e scaricare il materiale.

Trova il codice di errore
| Codice di errore | Prodotto | Categoria di apparecchiatura | Descrizione |
|---|---|---|---|
| 446 | Fanuc | Servo amplifier 400 alarms |
n AXIS : HARD DISCONNECT ALARM – A broken wire in the built–in pulse coder was detected by hardware. |
| 447 | Fanuc | Servo amplifier 400 alarms |
n AXIS : HARD DISCONNECT (EXT) – A broken wire in the separate detector was detected by hardware. |
| 448 | Fanuc | Servo amplifier 400 alarms |
n AXIS : UNMATCHED FEEDBACK ALARM – The sign of feedback data from the built–in pulse coder differs from that of feedback data from the separate detector. |
| 449 | Fanuc | Servo amplifier 400 alarms |
n AXIS : INV. IPM ALARM – 1) SVM: IPM (intelligent power module) detected an alarm. 2) α series SVU: IPM (intelligent power module) detected an alarm. |
| 45 | Baumüller | Operating system P0202 |
Communication error WinBASS controller |
| 4502 | Siemens | Simodrive 611 |
Channel %1 anachronism %2(%3) -> %4 |
| 453 | Fanuc | Servo amplifier 400 alarms |
n AXIS : SPC SOFT DISCONNECT ALARM – Software disconnection alarm of the α pulse coder. Turn off the power to the CNC, then remove and insert the pulse coder cable. If this alarm is issued again, replace the pulse coder. |
| 456 | Fanuc | Servo amplifier 400 alarms |
ILLEGAL CURRENT LOOP – The current control cycle settings (parameter No. 2004, bit 0 of parameter No. 2003, and bit 0 of parameter No. 2013) are incorrect. Possible problems are as follows. – For the two axes whose servo axis numbers (settings of parameter No. 1023) are an odd number followed by an even number (a pair of axes 1 and 2 or axes 5 and 6, for example), a different current control cycle is set for each of the axes. – The requirements for slaves needed for the set current control cycle, including the number, type, and connection method of them, are not satisfied. |
| 457 | Fanuc | Servo amplifier 400 alarms |
ILLEGAL HI HRV (250US) – Use of high–speed HRV is specified although the current control cycle is 200 μs. |
| 458 | Fanuc | Servo amplifier 400 alarms |
CURRENT LOOP ERROR – The current control cycle setting does not match the actual current control cycle. |
| 459 | Fanuc | Servo amplifier 400 alarms |
HI HRV SETTING ERROR – Of two axes having adjacent servo axis numbers (parameter No. 1023), odd number and even number, high–speed HRV control can be performed for one axis and not for the other. |
| 46 | Fanuc | Servo amplifier alarms |
When the magnetic contactor is turned on, the phase sequence of the power supply cannot be determined. |
| 46 to 47 | Baumüller | Operating system P0202 |
reserved Not assigned = 0 |
| 460 | Fanuc | Servo amplifier 400 alarms |
n AXIS : FSSB DISCONNECT – FSSB communication was disconnected suddenly. The possible causes are as follows: 1) The FSSB communication cable was disconnected or broken. 2) The power to the amplifier was turned off suddenly. 3) A low–voltage alarm was issued by the amplifier. |
| 461 | Fanuc | Servo amplifier 400 alarms |
n AXIS : ILLEGAL AMP INTERFACE – The axes of the 2–axis amplifier were assigned to the fast type interface. |
| 462 | Fanuc | Servo amplifier 400 alarms |
n AXIS : SEND CNC DATA FAILED – Because of an FSSB communication error, a slave could not receive correct data. |
| 463 | Fanuc | Servo amplifier 400 alarms |
n AXIS : SEND SLAVE DATA FAILED – Because of an FSSB communication error, a slave could not receive correct data. |
| 464 | Fanuc | Servo amplifier 400 alarms |
n AXIS : WRITE ID DATA FAILED – An attempt was made to write maintenance information on the amplifier maintenance screen, but it failed. |
| 465 | Fanuc | Servo amplifier 400 alarms |
n AXIS : READ ID DATA FAILED – At power–up, amplifier initial ID information could not be read. |
| 466 | Fanuc | Servo amplifier 400 alarms |
n AXIS : MOTOR/AMP COMBINATION – The maximum current rating for the amplifier does not match that for the motor. |